Wpływ konstrukcji bioreaktora wieżowego air-lift na szybkość wnikania tlenu do fazy ciekłej
Subtitle:The influence of the tower air-lift bioreactor geometry on the oxygen transfer rate in the apparatus
Creator:Głuszcz, Paweł ; Michalski, Henryk
Publisher:Komitet Biotechnologii PAN ; Instytut Chemii Bioorganicznej PAN
Date issued/created: Subject and Keywords: Abstract:The hydrodynamic and mass transfer parameters in water, in several types of tower-loopair-lift bioreactor were investigated. The following configurations of the apparatus were used forexperiments: internal-loop with eentral draft tube, internal-loop with static mixers in the drafttube, external-loop with various circulation tube diameters (0 < A^/Ar < 1), external-loop withperforated plates in the main zone (multistage reactor). The highest k^a eoefficients were obtainedin external-loop multistage reactor. A^/A^ ratio had significant influence on the main processparameters; gas holdup, liquid circulation velocity, volumetric oxygen transfer coefficient andmixing time.
Relation:Biotechnologia, vol.22, 3 (1993)-.
Volume: Issue: Start page: End page: Resource type: Detailed Resource Type: Format: Resource Identifier: Source:Biblioteka Instytutu Chemii Bioorganicznej PAN
Language: Language of abstract: Temporal coverage: Rights:Licencja Creative Commons Uznanie autorstwa-Na tych samych warunkach 4.0